• 3.6kV-24kV Indoor metal-clad withdrawable switchgear MV Switchgear
3.6kV-24kV Indoor metal-clad withdrawable switchgear MV Switchgear
discuss personally
Model
KYN28-7.2/1250-40
KYN28-3.6/630-40
KYN28-12/1250-50
KYN28-12/2500-3
Basic info
Brand ROCKWILL
Model NO. 3.6KV-24KV Indoor metal-clad withdrawable switchgear MV Switchgear
Rated voltage 7.2kV
Series KYN28-12
Product Detail

Description:

China KYN28-12 indoor metal-clad withdrawable switchgear (hereinafter short as switchgear) is a complete power distribution device for 3.6~24kV,3-phase AC 50Hz,single-bus and single-bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc.,so as to control, protect and monitor the system. The switchgear meets IEC298,GB3906-91.In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB,3AH5 from Siemens domestic ZN65A,and VB2 from GE, etc.,it is truly a power distribution device with good performance. In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  •  Altitude no higher than 2500m.

  • The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

image.png

Structure & Basic Components of Switchgear:

image.png

Overall size and weight:

image.png

Notice:

when the rated current is more than 1600A, cubicle width shall de 1000 mm, and cubicle height will be 1660mm and for schema of rear overhead line in.

  • Width of cabinet:650mm(compound insulation)or 800mm(air insulation) at current<1250A.

  • Width of cabinet:1000mm at current>1250A.

  • Depth of cabinet:1400mm,at cabinet width of 650mm(compoud insulation)when employing theconfiguration of incoming and outgoing cables.

  • Depth of cabinet:1500mm,at cabinet width of 6800mm(air insulation)when employing theconfiguration of incoming and outgoing cables.

  • Depth of cabinet:1600mm,when employing the configuration of rear overhead incoming andoutgoing cables.

    image.png

Structure Features:

image.png

Compartment:
Busbar compartment; circuit breaker compartment; cable compartment; low-voltage compartment.

  •  Main device: circuit breaker, contactor.

  •  Current transformers.

  •  Earthing switch.

  •  Voltage transformers.

  •  Support-bushing insulators.

  •  Bushing insulators.

  • Surge arresters.

  • Support insulators (reactance).

  • Main busbars.

  • Connecting (distribution) busbars.

  • Earth-fault current transformer.

  • Earthing conductor.

  • Metal movable particions.

  • Cable ducts (optionally).

  • Vent flaps.

Dimension:

image.png
Dimension in brackets means dimension of heavy-current cubicle.

image.png

What are the application scenarios of indoor metal armored pull-out switch cabinets? 

Industrial Applications:

  • In Industrial Enterprises:

  • Widely used in factories, mines, metallurgy, and chemical industries. They provide medium-voltage power distribution and protection for various production equipment such as large motors, transformers, and electric furnaces. For example, in a steel mill's rolling workshop, medium-voltage switchgear provides reliable power supply to the rolling motors and can quickly cut off the circuit in case of motor overload or short circuit, protecting the motor and the entire production line.

Commercial Buildings and Public Facilities:

  • In Commercial Buildings (e.g., shopping centers, office buildings, hotels) and Public Facilities (e.g., hospitals, schools, stadiums):

  • Used in medium-voltage distribution rooms. They provide power distribution and control for equipment within the buildings, such as elevators, air conditioning, and lighting. For instance, in a hospital, medium-voltage switchgear supplies stable power to various medical equipment and air conditioning systems, ensuring the normal operation of the hospital.

Substations:

  • In Medium-Voltage Substations:

  • Serves as the primary distribution equipment, receiving and distributing power from transmission lines. It can step down the medium-voltage power from the transmission lines and distribute it to various low-voltage lines, or distribute the power to other substations or end-users.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!